Interior moisture from building use and modern humidified heating
and cooling systems can create serious problems. In northern U.S. climates,
heated buildings will have winter-time relative humidity levels ranging
from 10%-35% Relative Humidity (RH). A house with four occupants generates
between 10 and 16 pounds of water a day (approximately 1 ½- 2 gallons)
from human residents. Moisture from food preparation, showering, or laundry
use will produce condensation on windows in winter climates.
If adequate ventilation is installed, damage to interior walls such as this can be prevented. NPS files.Photo: NPS files.
|
When one area
or floor of a building is air-conditioned and another area is not, there
is the chance for condensation to occur between the two areas. Most periodic
condensation does not create a long-term problem.
Humidified climate control systems are generally a major problem in
museums housed within historic buildings. They produce between 35%-55%
RH on average which, as a vapor, will seek to dissipate and equalize with
adjacent spaces. Moisture can form on single-glazed windows
in winter with exterior temperatures below 30°F and interior temperatures
at 70°F with as little as 35% RH. Frequent condensation on interior
window surfaces is an indication that moisture is migrating into exterior
walls, which can cause long-term damage to historic materials. Materials
and wall systems around climate controlled areas may need to be made of
moisture resistant finishes in order to handle the additional moisture
in the air. Moist interior conditions in hot and humid climates will generate
mold and fungal growth. Unvented mechanical equipment, such as gas stoves,
driers, and kerosene heaters, generate large quantities of moisture. It
is important to provide adequate ventilation and find a balance between
interior temperature, relative humidity, and airflow to avoid interior
moisture that can damage historic buildings.
Moisture from maintenance and construction materials can cause
damage to adjacent historic materials. Careless use of liquids to wash
floors can lead to water seepage through cracks and dislodge adhesives
or cup and curl materials. High-pressure power washing of exterior walls
and roofing materials can force water into construction joints where it
can dislodge mortar, lift roofing tiles, and saturate frame walls and masonry.
Replastered or newly plastered interior walls or the construction of new
additions attached to historic buildings may hold moisture for months;
new plaster, mortar, or concrete should be fully cured before they are
painted or finished. The use of materials in projects that have been damaged
by moisture prior to installation or have too high a moisture content
may cause concealed damage.